Advantages of our double-pipe air source water heater--11 KW
1) It can not only work as a air conditioner, but also by the same time provide your with hot water
High efficiency/ good COP index performance
2) Safe and convenient to use:
3) Automatic control:
a. Temperature checking function
High/Low pressure protection and insufficient water flow protection; automatic unit on/off timer clock.
b. Automatic reversing defrosting function
c. Unit runs automatically according to set water temperature.
4) Qualified components: Branded compressor (Toshiba)
Detailed Description:
The parameters of our double-pipe air source water heater as below,
Model: CS-RS-82
Ambient temp.
Performance |
Outdoor temp(℃) |
43℃ |
20℃ |
2℃ |
Heating capacity (W) |
16300 |
11900 |
7000 |
Average input (W) |
2600 |
2400 |
2200 |
Max. input (W) |
3400 |
3200 |
2090 |
COP (W/W) |
6.27 |
4.95 |
3.34 |
Hot water supply(L/h) |
460 |
245 |
140 |
Flow rate of tested circulation pump(t/h) |
2.85 |
2.84 |
2.84 |
Temp. difference of in/out water (℃) |
5 |
5 |
2 |
Hot water temp. (℃) |
55 |
Net weight (Kg) |
94 |
Gross weight (Kg) |
98 |
Power supply |
220V~50Hz |
Refrigerant |
R410A |
Size(mm) |
740x340x1020 |
Packing size(mm) |
850x420x1170 |
Air to Water Heat pump
(King Heater)
Specifications
Heat Pump Water Heater
1) Environmental Protected
2) Save Energy Cost
3) Automatic Control
4) CE EMC TUV
The parameters of Air Source Heating Pump Air Water Heater
features as below:
Model |
CS-RS-140 |
Outdoor temp.
Performance |
43℃ |
20℃ |
2℃ |
Heating capacity (W) |
24000 |
18500 |
11800 |
Average input (W) |
5000 |
4750 |
4100 |
Max. input (W) |
6250 |
6240 |
6400 |
COP (W/W) |
4.8 |
3.89 |
2.87 |
Hot water supply(L/h) |
688 |
420 |
240 |
Flow rate of tested circulation pump(t/h) |
3.45 |
3.45 |
3.3 |
Temp. difference of in/out water (℃) |
4.5 |
3 |
1.1 |
Hot water temp. (℃) |
55 |
Net weight (Kg) |
200 |
Gross weight (Kg) |
230 |
Power supply |
380V~60Hz |
Refrigerant |
R410A |
Size(mm) |
880×850×1240 |
Packing size(mm) |
880×880×1250 |
Model |
CS- RS-280 |
Outdoor temp.
Performance |
43℃ |
20℃ |
2℃ |
Heating capacity (W) |
47000 |
33000 |
18600 |
Average input (W) |
9100 |
9000 |
8000 |
Max. input (W) |
11890 |
12100 |
12100 |
COP (W/W) |
5.1 |
3.67 |
2.33 |
Hot water supply(L/h) |
1200 |
800 |
370 |
Flow rate of tested circulation pump(t/h) |
10.3 |
10.2 |
10.6 |
Temp. difference of in/out water (℃) |
3 |
3 |
2 |
Hot water temp. (℃) |
55 |
Net weight (Kg) |
380 |
Gross weight (Kg) |
452 |
Power supply |
380V~60Hz |
Refrigerant |
R410A |
Size(mm) |
1530×800×1350 |
Packing size(mm) |
1530×800×1350 |
|